HLS SERIES – HIGH TDS BRACKISH WATER RO 1,400 TO 6,600 GPD

Commercial Reverse Osmosis Water Treatment for High TDS Brackish Water up to 15,000 PPM

  • 1,400 to 6,600 Gallons/Day Reverse Osmosis Systems
  • For Feed Water TDS up to 15,000 PPM

Designed to produce low dissolved solids water from high TDS brackish well water or similar source water, these RO systems use high efficiency reverse osmosis membranes in FRP membrane housings. The product water is used in applications such as water stores, whole house, ice makers, humidification, misting and a wide variety of other applications.

HLS Series RO systems incorporate careful design steps taken to minimize the highly corrosive nature of these brackish waters. All high pressure lines and components are made of corrosion resistant materials. These BWRO systems operate at pressures between 350 and 500 psi.

These reverse osmosis systems use the proven, reliable components and are mounted on a sturdy powder-coated metal frame. There are numerous design details learned from years of experience that are incorporated in our water filtration systems. Our process and fluid design ensures an optimum membrane life and minimizes the membrane fouling.

Contact us for a Personalized Consultation

HLS Series Commercial RO Brackish Water System Benefits

  • Compact, economical solution for high TDS brackish feed water
  • Over 38 years of experience is reflected in our quality
  • Heavy Duty, Powder Coated Frame
  • Proven components used throughout the system
  • Conservatively engineered for reliable long term performance
  • Factory tested to ensure trouble-free operation

HLS Series Commercial RO Brackish Water System Product Line

RO System Model No.

RO System
Capacity

RO Membrane
Elements

Line Sizes
(NPT, Inches)

RO System
Dimensions (in/cm)

Approx. Shipping Weight
(Lb/Kg)

GPD

m³/day

Qty.

Size
(Dia.×L)

Inlet

Perm.

Conc.

Length

Depth

Height

HLS-14A-116

1,400

5.3

1

4 × 40

1

½

½

20/51

24/61

55/140

400/181

HLS-24A-116

3,500

13.2

2

4 × 40

1

½

½

20/51

24/61

55/140

425/193

HLS-34A-216

4,600

17.4

3

4 × 40

1

½

½

20/51

32/82

55/140

450/204

HLS-44A-216

5,500

21

4

4 × 40

1

¾

¾

20/51

32/82

55/140

475/216

HLS-54A-216

6,200

23.5

5

4 × 40

1

¾

¾

20/51

32/82

55/140

500/227

HLS-64A-216

6,630

25

6

4 × 40

1

¾

¾

20/51

32/82

55/140

525/238

Notes and Voltage/ Ordering Information

  • All dimensions and weights are approximate.
  • Capacity Basis: 24 hrs/day
  • Systems rated at: 77°F (25°C) using 15,000 ppm sodium chloride solution operating at approx. 350-500 psi pressure.
  • Minimum feed pressure to RO System: 40-60 PSI. System capacity changes significantly with water temperature
  • Chlorine must be removed with a carbon filter prior to the RO system, if present in feed water.
  • Pretreatment for water hardness using a softener or antiscalant injection should be added to avoid scaling the membranes.
  • Feed water turbidity: Less than 1 NTU; Feed water silt density index (SDI): 3 maximum. If exceeded, pretreatment with media filter recommended. All pretreatment equipment and SDI test kits are available from Applied Membranes.
  • Voltage: Please add our voltage codes to the end of the model number when ordering.
    Example: HLS-14A-216 = 220/230v, 1 ph, 60 hz.
  • Voltage Codes:
  • 216 = 220/230v, 1ph, 60hz
  • 236 = 220/230v, 3ph, 60hz
  • 436 =460/480v, 3ph, 60hz

Recommended Pre-Treatment Equipment (Sold Separately)

  • Carbon filter
  • Water Softener
  • Multi-media filter
  • Antiscalant Injection

Standard Equipment for HLS Series Commercial RO Brackish Water Systems

  • Thin Film Composite RO Membranes
  • FRP Membrane Pressure Vessels
  • 5 Micron 20” Cartridge Filter & Housing
  • Feed Water Temperature
  • Automatic Inlet Feed Solenoid Valve
  • Permeate, Concentrate & Recycle Flowmeters
  • RO System Control Valve, Stainless Steel
  • Recycle Control Valve, Stainless Steel
  • Low Pressure Pump Protection
  • High Pressure Stainless Steel RO Pump
  • Automatic Membrane Flush with Fresh Water Pump
  • Liquid Filled Pressure Gauges for Filter IN/OUT and System Pressures
  • Feed and Permeate TDS Displayed on Controller LED with Percent Rejection
  • RO System ON/OFF With 2-Level Tank Floats
  • Stainless Steel and Corrosion Resistant Materials on High Pressure Side
  • Powder Coated Carbon Steel Frame
  • Boxed and Palletized For Shipment

Microprocessor Controller for Automatic Operation

Monitors and/or Controls:

  • Inlet valve
  • Delayed start-up of high pressure pump
  • Feed water flush at system shut-down
  • Low pressure switch
  • On/Off with tank level
  • Permeate Water Quality 
  • Pre-treatment backwash/lockout
  • Feed Water Quality and percent rejection
  • Water Temperature
  • Operating hours
  • RO tank full override

UL508A Labeled

I-ROC150S

Controller Features:

  • Backlit LED Display
  • Multi-function keypad
  • Visual and audible alarm & silence key
  • Programmable time delays, set-points and
    flush mode
  • Visual indicator alarm light
  • Low pressure automatic restart

LED Display:

  • Permeate TDS
  • Feed TDS with % Rejection
  • Water Temperature
  • Operating Hours
  • Operating Status
  • Alarm condition

Common Applications for HLS Series Commercial RO Brackish Water Systems

  • Spot Free Rinse/Car Wash
  • Water Stores
  • Whole House
  • Laboratories
  • Large Office
  • Institutions
  • Ice Makers
  • Humidification
  • Misting
  • Commercial
  • Manufacturing
  • And a wide variety of other applications

Optional Add-On Parts and Equipment for Commercial RO Systems

AMI’s HLS Series High TDS RO Systems are available with a wide variety of optional add-on equipment. All assemblies include hardware and mounting equipment for easy upgrade to your new or existing system installation.

Wall Mount Filter Cartridges

Includes mounting bracket and Isolation Valves to close the line when changing the filter cartridge.

Part # A711

Filter cartridge must be ordered separately – common options are shown below. Any 20″ Big Blue size cartridge can be installed. Click here to view our complete filter cartridge product selection.

Click Here to visit the Media Filtration section of our site for detailed information on the full line of media filtration products we carry.

Softeners & Media Filtration Pre/Post Treatment

AMI Media filters feature fully automatic backwash or regeneration for easy, trouble free maintenance. Ensure superior system operation and extended membrane life by providing proper pretreatment to the incoming feed water on a continuous basis. Common pretreatment or post-treatment methods include:

  • Single or Twin Water Softener to remove hardness and scale.
  • Multi-Media Filter for sediment filtration to approximately 10 microns.
  • Carbon Filter to remove chlorine.
  • Calcite Filter to neutralize the pH of the RO product water.

Click Here to visit the Media Filtration section of our site for detailed information on the full line of media filtration products we carry.

Chemical Injection System

Antiscalant injection as an alternative to a water softener for scale control, or Sodium Metabisulfite injection as an alternative to a carbon filter to remove chlorine.

Water Quality Monitors

Pre-packaged wall-mountable water quality monitoring controls allow you to monitor the quality of the incoming feed or RO product water. Assembly includes the monitor, enclosure and sensor.

Available Options for Monitoring Incoming Feed Water Quality:
  • ORP – 60Hz Part # A246, 50Hz Part # A247
  • pH – 60Hz Part # A244, 50Hz Part # A245
Available Options for Monitoring RO Product Water Quality:
  • Total Dissolved Solids (TDS) – 60Hz Part # A242, 50Hz Part # A243
  • Resistivity – 60Hz Part # A248, 50Hz Part # A249
  • pH – 60Hz Part # A244, 50Hz Part # A245

Ultraviolet (UV) Systems

Add an ultraviolet water sterilizer for a 99.9% reduction of bacteria and viruses in the feed and/or permeate line.

Note: For feed line, wall-mount filter cartridge assembly shown above is required.

Tank Pressure Controls

To automatically turn the RO system on or off with the permeate storage tank level. For use with a pressurized storage tank (sold separately).

  • 220v/60Hz – Part # A621

Pressurized Storage Tank

Pressurized permeate storage tank available in 40 or 80 gallon volume. Assembly includes tank, valve, piping, tubing, and pressure gauge.

  • 40 Gallon Tank Assembly – Part # A612-40
  • 80 Gallon Tank Assembly – Part # A612-80

Tank Level Controls

Turns system on or off according to the water level in an atmospheric storage tank.

  • Dual float assembly provides system on/off controls.
    Part # YFL2PPAS
  • Triple float assembly provides system on/off as well as low level protection on/off for a repressurization pump.
    Part # YFL3PPAS

Atmospheric storage tank and repressurization pump are sold separately.

Atmospheric Storage Tank

Atmospheric Permeate Storage tank. Assembly includes bulkheads and vent filter. For use with Tank Level Controls (sold separately).

  • 200 Gallon Part # A613-200
  • 400 Gallon Part # A613-500

Delivery System

20 GPM, 50 PSI, 220v/1ph/50-60Hz

Includes Pump, 40 Gallon Pressure Tank, Controls and Fittings

Part # A606-216

Prefilter Pressure Gauge

To allow for monitoring of the in and out pressure of the prefilter in order to indicate when the cartridge needs to be changed. Assembly includes pressure gauge and fittings.

Part # A623

Floor Casters Kit

2 Locking casters and 2 Swivel casters to mount at the base of the stand for ease of system mobility.

Part #: A625

Replacement Parts & Consumables for HLS Series Brackish Water Reverse Osmosis Systems

Give us a call today at 604-878-8092. Let’s discuss your unique application needs.