J Series – 7,000 to 28,800 GPD

J SERIES – REVERSE OSMOSIS SYSTEMS 7,000 TO 28,800 GPD

Designed to produce low dissolved solids water from tap or well water, these high quality commercial RO systems use highly efficient RO Membranes. The RO product water is used in commercial and light industrial applications such as rinse water, pharmaceutical, food processing, bottled water, hotels, beverage, hospitals, and a wide variety of other applications.

Series J Reverse Osmosis Water Filtration Systems use 4”×40” RO membrane elements. RO Membrane Housing Pressure vessels contain one or two reverse osmosis membrane elements each and are mounted in a horizontal position.

RO Systems are shipped ready for immediate on-line service. The high quality, innovative design of AMI’s J-Series RO Systems has given these systems the reputation as the most reliable and cost effective solution for tap or well water purification.

Contact us for a Personalized Consultation
  • Available in Single or Double Pass RO System configurations
  • Over 30 years of experience in reflected in our quality
  • Manufactured in the USA in our ISO 9001:2015 Certified Facilities
  • Heavy duty powder coated frame
  • Stainless steel high pressure components
  • Stainless steel multi-stage centrifugal  pump
  • Highly efficient, customizable and economical
  • Microprocessor controlled operation
  • Conservatively engineered for reliable, long term performance
  • Factory tested to ensure trouble-free operation

J Series Commercial Reverse Osmosis Systems Ordering Information

RO System Model No.

RO System Capacity

# of Elements

Line Sizes
(Inches)

GPM

GPD

m³/hr

Inlet

Perm.

Conc.

J-44A

5

7,000

1.1

4

1

¾

¾

J-54A

6

8,500

1.3

5

1

¾

¾

J-64A

7

10,000

1.6

6

1

¾

¾

J-74A

8

11,500

1.8

7

1

¾

¾

J-84B

9

13,000

2.0

8

1

¾

J-104B

10

14,400

2.3

10

1

¾

J-124B

12

17,300

2.7

12

1

¾

J-144B

14

20,000

3.2

14

1

¾

J-164B

16

23,000

3.6

16

1

¾

J-184B

18

26,000

4.1

18

1

¾

J-204B

20

28,800

4.5

20

1

¾

J Series Commercial Reverse Osmosis Systems Dimensions

RO System Model No.

Standard System Dimensions
(in/cm)


Approx Weight
(lb/kg)

 

System with CIP Dimensions (in/cm)

 

Length

Width

Height

Length Width Height

J-44A

80/203

35/89

75/191

1,070/485

 112/285  45/114 75/191

J-54A

80/203

35/89

75/191

1,130/513

 112/285   45/114   75/191

J-64A

80/203

35/89

75/191

1,190/540

 112/285   45/114  75/191 

J-74A

80/203

35/89

75/191

1,275/578

 112/285   45/114  75/191 

J-84B

100/254

35/89

75/191

1,410/640

 132/335  45/114  75/191 

J-104B

100/254

35/89

75/191

1,530/694

 132/335  45/114  75/191 

J-124B

100/254

35/89

75/191

1,610/776

 132/335  45/114  75/191 

J-144B

100/254

35/89

75/191

1,830/830

 132/335   45/114  75/191 

J-164B

100/254

35/89

75/191

1,950/885

 132/335   45/114  75/191 

J-184B

100/254

35/89

80/203

2,070/939

 132/335   45/114  75/191 

J-204B

100/254

35/89

80/203

2,190/993

 132/335   45/114  75/191 

Examples of AMI J Series RO System Installations Currently In Service:

Provides Water for an Island Resort from Brackish Well Water
Water for Food Processing – with SS Carbon Tanks & Insulated Pipes
Reverse Osmosis for Bottled Water Production
Provides Water for an Island Resort from Brackish Well Water

Notes and Voltage/ Ordering Information

  • All dimensions and weights are approximate.
  • RO System Capacity Basis: 24 hrs/day.
  • RO Systems rated at: 77°F (25°C) using 2000 ppm sodium chloride solution operating at approx. 225-250 psi pressure.
  • Minimum feed pressure to RO System: 40-60 PSI.
  • RO System capacity changes significantly with water temperature.
  • For higher TDS a water analysis must be supplied and could result in modifications to the RO system design.
  • Chlorine must be removed with a carbon filter or with chemical injection prior to the RO system, if present in feed water.
  • Pretreatment for water hardness using a softener or antiscalant injection should be added to avoid scaling the RO membranes.
  • Feed water turbidity: Less than 1 NTU; Feed water silt density index (SDI): 3 maximum. If exceeded, pretreatment with media filter recommended. All pretreatment equipment and SDI test kits are available from Applied Membranes.

Please add our voltage codes to the end of the model number when ordering:
Example: J-84B-236 = 220/230v/3 ph/60 Hz

Voltage Codes
Single Phase Not Available

  • 236= 220 or 230v/ 3ph/ 60hz
  • 436= 460 or 480v/ 3ph/ 60 Hz
  • 235= 220v/3ph/50hz
  • 335= 380v/3ph/50hz

Standard Equipment

  • Thin Film Composite RO Membranes
  • Stainless steel multi-stage centrifugal RO pump
  • Stainless steel RO membrane pressure vessels
  • Powder coated carbon steel skid
  • 5 Micron Sediment Filter
  • 316SS high pressure piping and Sch. 80 PVC low pressure piping
  • Motorized automatic inlet feed valve
  • Feed pump throttling valve, SS
  • Concentrate & recycle panel mounted SS flow control valves
  • Automatic membrane feed flush
  • Low inlet pressure switch
  • High pressure switch
  • 4) Panel mounted liquid filled pressure gauges: Filter in/out, pump, concentrate
  • 3) Panel mounted flowmeters: Product, reject and recycle
  • Product TDS (or Conductivity)  with digital display readout
  • Cleaning ports
  • System on/off with 2-level tank floats

Microprocessor Controller for Automatic Operation

Monitors and/or Controls:

  • Inlet valve
  • Delayed start-up of high pressure pump
  • Feed water flush at system shut-down
  • Low pressure switch
  • On/Off with tank level
  • Permeate Water Quality (TDS)
  • Pre-treatment backwash/lockout
  • Permeate TDS (or conductivity)
  • Feed TDS (or conductivity) and percent
    rejection
  • Water Temperature
  • Operating hours
  • RO tank full override
  • Auxiliary pump or valve control (optional)

UL508A Labeled

I-ROC150S

Controller Features:

  • Backlit LED Display
  • Multi-function keypad
  • Visual and audible alarm & silence key
  • Programmable time delays, set-points and flush mode
  • Visual indicator alarm light
  • Low pressure automatic restart

LED Display:

  • Permeate TDS
  • Feed TDS with % Rejection
  • Water Temperature
  • Operating Hours
  • Operating Status
  • Alarm condition
  • Rinse Water
  • Pharmaceutical
  • Food Processing
  • Bottled Water
  • Hotels, Resorts
  • Beverage
  • Hospitals
  • Laboratory

Optional Equipment

  • Stainless steel boost or repressurization pump
  • pH monitor for feed or for permeate
  • Chemical injection
  • Pre-treatment: Softener, carbon, media
  • ORP monitor/controller
  • Filter housing upgrade to SS
  • Turbidity monitor
  • FRP membrane housings
  • Low energy membranes
  • Clean-in-place – doubles as a permeate flush system
  • Permeate divert to drain
  • UV system, feed or permeate

Replacement Parts & Consumables

Give us a call today at 604-878-8092. Let’s discuss your unique application needs.

© 2024 Pureworld Solutions Inc.