XL Series – Low Energy 2,000 to 10,000 GPD

XL SERIES – LOW ENERGY RO SYSTEMS 2,000 TO 10,000 GPD

Designed to produce low dissolved solids water from tap or well water, these small commercial Low Energy RO systems use extra low energy XLE reverse osmosis membranes which run at 100-140 psi. The product water is used in applications such as spot free rinse, water stores, whole house, labs, ice makers, humidification, misting and a wide variety of other applications.

Part of the L-series family (other systems include L and HL series), these complete reverse osmosis systems are best suited for water of less than 1,000 PPM total dissolved solids (TDS). The systems use proven, reliable components and are mounted on a sturdy powder-coated metal frame. There are numerous design details, learned from years of experience that are incorporated in our systems. Our process and fluid design ensures an optimum membrane life and minimizes the membrane fouling.

Contact us for a Personalized Consultation
  • Significantly reduce your operating cost with the use of Low Energy RO Systems using XLE RO Membranes
  • Over 30 years of experience is reflected in our quality
  • Compact, Heavy Duty, Powder Coated Frame
  • Proven components used throughout the RO system
  • Conservatively engineered for reliable long term performance
  • Factory tested to ensure trouble-free operation

Model No.

System Capacity

Qty. of 4×40 Membrane Elements (XLE)

Line Sizes
(NPT, Inches)

System Dimensions
(in/cm)

Approx. Shipping Weight
(Lb/Kg)

GPD

m³/day

Inlet

Perm.

Conc.

Length

Depth

Height

XL-14A-216

2,000

7.5

1

¾

½

½

20/51

28/71

54/137

275/125

XL-24A-216

4,000

15

2

¾

½

½

20/51

28/71

54/137

300/136

XL-34A-216

5,800

22

3

¾

½

½

20/51

28/71

54/137

325/147

XL-44A-216

7,500

28

4

¾

½

½

20/51

34/87

54/137

350/159

XL-54A-216

9,000

34

5

¾

½

½

20/51

34/87

54/137

375/170

XL-64A-216

10,000

38

6

¾

½

½

20/51

34/87

54/137

400/181

Notes and Voltage/ Ordering Information

  • All dimensions and weights are approximate.
  • Capacity Basis: 24 hrs/day
  • Systems rated at: 77°F (25°C) using 1,000 ppm sodium chloride solution operating at approx. 200 psi pressure. System capacity changes significantly with water temperature. For higher TDS a water analysis must be supplied and could result in modifications to the system or changing from XL to L or HL series system.
  • Minimum feed pressure to RO System: 40-60 PSI. 
  • Chlorine must be removed with a carbon filter or with chemical injection prior to the RO system, if present in feed water. 
  • Pretreatment for water hardness using a softener should be added to avoid scaling the membranes.
  • Feed water turbidity: Less than 1 NTU; Feed water silt density index (SDI): 3 maximum. If exceeded, pretreatment with media filter recommended. All pretreatment equipment and SDI test kits are available from Applied Membranes.
  • Voltage Codes:  216 = 220 -240v/ 1ph/ 60hz • 215 = 220-240v/1ph/50hz .
    Three phase or other voltages not available with XL Series. See Series L or HL.

Standard Equipment

  • Thin Film Composite Extra Low Energy Membranes
  • Stainless Steel Membrane Pressure Vessels
  • 5 Micron 20” Cartridge Filter & Housing
  • Automatic Inlet Feed Solenoid Valve
  • Permeate Flowmeter
  • Concentrate Flowmeter
  • System Control Valve
  • Recycle Control Valve
  • Low Pressure Pump Protection
  • Stainless Steel Multistage RO Pump with SS Pump Throttling Valve
  • Automatic Membrane Flush
  • Liquid Filled Pressure Gauge for System Pressure
  • Feed TDS and Percent Rejection Displayed on Controller LED
  • Product TDS Displayed on Controller LED
  • System On/Off with Tank Level (Tank Floats Included)
  • Powder Coated Carbon Steel Frame
  • Boxed and Palletized for Shipment

Microprocessor Controller for Automatic Operation

Monitors and/or Controls:

  • Inlet valve
  • Delayed start-up of high pressure pump
  • Feed water flush at system shut-down
  • Low pressure switch
  • On/Off with tank level
  • Permeate Water Quality (TDS)
  • Pre-treatment backwash/lockout
I-ROC300 Controller for Automatic Operation

Controller Features:

  • Backlit LED Display
  • LED indicator light for system status/alarm
  • Front panel access port for calibration of TDS sensor
  • LED indicator light for water quality (TDS)
  • Start-up and shut-down with tank level
  • Feed flush at shut-down
  • Low pressure shut-down
  • Low pressure automatic restart
  • Delayed start-up of high pressure pump

LED Display:

  • Permeate TDS
  • Operating Status
  • Alarm Condition
  • Spot Free Rinse/Car Wash
  • Water Stores
  • Whole House
  • Laboratories
  • Large Office
  • Institutions
  • Ice Makers
  • Humidification
  • Misting
  • Commercial
  • Manufacturing
  • Rinse Water And a wide variety of other applications

Optional Add-On Parts and Equipment for Low Energy Commercial RO Systems

AMI’s XL Series Energy Saving RO Systems are available with a wide variety of optional add-on equipment. All assemblies include hardware and mounting equipment for easy upgrade to your new or existing system installation.

Wall Mount Filter Cartridges

Includes mounting bracket and Isolation Valves to close the line when changing the filter cartridge.

Part # A711

Filter cartridge must be ordered separately – common options are shown below. Any 20″ Big Blue size cartridge can be installed. Click here to view our complete filter cartridge product selection.

Pretreatment Options Available:

  • Block Carbon Filter Cartridges Block Carbon filter cartridges produce no carbon fines.

Post-treatment Options Available:

  • Calcite Filter Cartridge to neutralize the pH of the RO permeate water – Filter Model H-F4220CALCITE Click for Product Details
  • DI Filter Cartridge with Mixed-Bed Deionization Resin for ultrapure applications – Filter Model: H-F4220DI Click for Product Details

Softeners & Media Filtration Pre/Post Treatment

AMI Media filters feature fully automatic backwash or regeneration for easy, trouble free maintenance. Ensure superior system operation and extended membrane life by providing proper pretreatment to the incoming feed water on a continuous basis. Common pretreatment or post-treatment methods include:

  • Single or Twin Water Softener to remove hardness and scale.
  • Multi-Media Filter for sediment filtration to approximately 10 microns.
  • Carbon Filter to remove chlorine.
  • Calcite Filter to neutralize the pH of the RO product water.

Click Here to visit the Media Filtration section of our site for detailed information on the full line of media filtration products we carry.

Chemical Injection System

Antiscalant injection as an alternative to a water softener for scale control, or Sodium Metabisulfite injection as an alternative to a carbon filter to remove chlorine.

Water Quality Monitors

Pre-packaged wall-mountable water quality monitoring controls allow you to monitor the quality of the incoming feed or RO product water. Assembly includes the monitor, enclosure and sensor.

Available Options for Monitoring Incoming Feed Water Quality:
  • ORP – 60Hz Part # A246, 50Hz Part # A247
  • pH – 60Hz Part # A244, 50Hz Part # A245
Available Options for Monitoring RO Product Water Quality:
  • Total Dissolved Solids (TDS) – 60Hz Part # A242, 50Hz Part # A243
  • Resistivity – 60Hz Part # A248, 50Hz Part # A249
  • pH – 60Hz Part # A244, 50Hz Part # A245

Ultraviolet (UV) Systems

Add an ultraviolet water sterilizer for a 99.9% reduction of bacteria and viruses in the feed and/or permeate line.

Note: For feed line, wall-mount filter cartridge assembly shown above is required.

Tank Pressure Controls

To automatically turn the RO system on or off with the permeate storage tank level. For use with a pressurized storage tank (sold separately).

  • 220v/60Hz – Part # A621

Pressurized Storage Tank

Pressurized permeate storage tank available in 40 or 80 gallon volume. Assembly includes tank, valve, piping, tubing, and pressure gauge.

  • 40 Gallon Tank Assembly – Part # A612-40
  • 80 Gallon Tank Assembly – Part # A612-80

Tank Level Controls

Turns system on or off according to the water level in an atmospheric storage tank.

  • Dual float assembly provides system on/off controls.
    Part # YFL2PPAS
  • Triple float assembly provides system on/off as well as low level protection on/off for a repressurization pump.
    Part # YFL3PPAS

Atmospheric storage tank and repressurization pump are sold separately.

Atmospheric Storage Tank

Atmospheric Permeate Storage tank. Assembly includes bulkheads and vent filter. For use with Tank Level Controls (sold separately).

  • 200 Gallon Part # A613-200
  • 400 Gallon Part # A613-500

Delivery System

20 GPM, 50 PSI, 220v/1ph/50-60Hz

Includes Pump, 40 Gallon Pressure Tank, Controls and Fittings

Part # A606-216

Prefilter Pressure Gauge

To allow for monitoring of the in and out pressure of the prefilter in order to indicate when the cartridge needs to be changed. Assembly includes pressure gauge and fittings.

Part # A623

Floor Casters Kit

2 Locking casters and 2 Swivel casters to mount at the base of the stand for ease of system mobility.

Part #: A625

Replacement Parts & Consumables for HL Series Reverse Osmosis Systems

Give us a call today at 604-878-8092. Let’s discuss your unique application needs.

© 2024 Pureworld Solutions Inc.